Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Phase: | Three Phase |
| Type: | On-line |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Zhejiang Gangkong Electric Co., Ltd. is a comprehensive enterprise engaged in the research and development, manufacturing, and sales of UPS uninterruptible power supply, EPS fire emergency power supply, intelligent DC screen, solar off grid/grid connected power generation system, energy storage system, and other products. After years of development, Gangkong Electric has become a well-known manufacturer and supplier of comprehensive solutions in the fields of network energy, data centers, new energy, energy storage, and emergency response.
| input | Voltage | single-phase220VAC±20% | ||
| Frequency | 50Hz±10% | |||
| output | Voltage | During normal operation:same mains voltage during emergency:220VAC±3% | ||
| Frequency | During normal operation:synchronized with mains power;during emergency operation:50Hz±5% | |||
| Wave form | Sine wave(THD≤3%) | |||
| Output branch | 3-way (expandable) | |||
| Output branch type | Continuous,non continuous,and fire linkage | |||
| Battery | Battery form | Sealed water free | ||
| Nominal voltage | 24VDC | 48VDC | 192VDC | |
| Charging time | <24h | |||
| Conversion time | <5s(Customizable in special circumstances,≤0.25s,≤2.5ms,Oms) | |||
| Emergency standby time | 90min(Can be determined as needed) | |||
| Overload capacity | 120%Normal operation;150%1min | |||
| Protection function | Overvoltage,undervoltage,overcurrent,short circuit protection | |||
Communication |
RS232/RS485,Communication protocol:Modbus or according to customer requirements; Remote monitoring card SNMP(optional) |
|||
| Noise(1m distance) | Normal:No noise during emergency:<50dB | |||
A |
Relative temperature | 10-90% | ||
| ambient temperature | Below zero20°-40ºC | |||
| ltitude temperature | ≤2000m(>At 2000m,forevery 100m increase,the power is reduced by 1%) | |||
| Adapt to load | Suitable for various lighting loads | |||
| input | Voltage | Single phase 220VAC±20% | ||
| Frequency | 50Hz±10% | |||
| output | Voltage | During normal operation:same mains voltage during emergency:220VAC±3% | ||
| Frequency | During normal operation:synchronized with mains power;during emergency operation:50Hz±5% | |||
| Wave form | sine wave(THD≤3%) | |||
| Output branch | 3-way (expandable) | |||
| Output branchtype | Continuous,non continuous,and fire linkage | |||
| Battery | Battery form | Sealed water free | ||
| Nominal voltage | 24VDC | 48VDC | 192VDC | |
| Charging time | <24h | |||
| Conversion time | <5s(Customizable in special circumstances,≤0.25s,≤2.5ms,0ms) | |||
| Emergency standby time | 90min(Can be determined as needed) | |||
| Overload capacity | 120%working normally;150%1min | |||
| Protection function | Overvoltage,undervoltage,overcurrent,short circuit protection | |||
| Communication | RS232/RS485,Communication protocol:Modbus or according to customer requirements; Remote monitoring card SNMP(optional) |
|||
| Noise(1m distance) | Normal:No noise during emergency:50dB | |||
| environment | Relative temperature | 10-90% | ||
| ambient temperature | Below zero 20ºC-40ºC | |||
| Atitude temperature | ≤2000m(>At 2000m,for every 100m increase,the power is reduced by 1%) | |||
| Adapt to load | Suitable for various lighting loads | |||
| capacity* | 1000VA/800W | |||
| in on imetntimncta A Battery eficency output input | Voltage range | Minimum conversion voltage | 160 VAC/140 VAC/120 VAC/110 VAC±5%(The ambient temperature is less than 35 degrees Celsius) (According to load ratio 100%-80%/80%-70%/70%-60%/60%-0) |
|
| Minimum recovery voltage | 175 VAC/155 VAC/135 VAC/125 VAC±5%(The ambient temperature is less than 35 degrees Celsius) (According to load ratio100%-80%/80%-70%/70%-60%/60%-0) |
|||
| Maximum conversion voltage | 300 VAC±5% | |||
| Maximum recovery voltage | 290 VAC±5% | |||
| Frequency range | 40Hz~70Hz | |||
| Phase | Single phase grounded type | |||
| Power specifications | ≥0.99@220-230 VAC(input voltage) | |||
| output voltage | 200/208/220/230/240 VAC | |||
| Range of mains voltage | ±1%(Battery mode) | |||
| Frequency range (synchronous range) |
47~53Hzor57~63Hz | |||
| Frequency range (battery mode) |
50Hz±0.25Hz or 60Hz±0.3Hz | |||
overload |
The ambient temperature is less than 35 degrees Celsius: 105%~110%:UPS will automatically shut down after 10minutes in battery mode,or switch to bypass mode when input is normal; 110%~130%:UPS will automatically shut down after 1 minute in battery mode,or switch to bypass mode when input is normal; >130%:UPS automatically shuts down after 3 seconds in battery mode,or switches to bypass mode when input is normal |
|||
| Current to peak ratio | 3:1 | |||
| Harmonic distortion | ≤3%THD(Linear load);≤5%THD(Nonlinear load) | |||
| From mains mode to battery mode | zero | |||
| Variable frequency to bypass | 4ms(Under standard conditions) | |||
| Waveform (battery mode) |
Pure sine wave | |||
| Mains mode | 88% | |||
| Battery mode | 83% | |||
| Battery capacity | Depending on the external battery | |||
| Number of batteries | 2 3 | |||
| Charging current | 1A/2A/4A/6A | |||
| Charging voltage | 27.3VDC±1% 41.0VDC±1% | |||
| Size depth,widthand height(mm) | 355X145X225 | |||
| Net weight(kg) | 8.65 | 6.0 | ||
| Operating humidity | 20-90%RH@0-40ºC(No condensation) | |||
| noise | Less than 50dBA@1rice | |||
| intelligent RS-232 or USB(Apolegamy) | Support Windows@2000/2003/XP/Vista/2008/7,Linux,Unix or MAC | |||
| Apolegamy SNMP | Supports power management by SNMP administrators and web browsers | |||
| Capacity* | 2000VA/1600W | 3000VA/2400W | ||||
| effcenoy output input | Voltage range | Minimumcnversio votge | 160 VAC/140 VAC/120 VAC/110 VAC±5%(The ambient temperature is less than 35 degrees Celsius) (According to load ratio 100%-80%/80%-70%/70%-60%/60%-0) |
|||
Minimum recoveryvoltage |
175 VAC/155 VAC/135 VAC/125 VAC±5%(The ambient temperature is less than 35 degrees Celsius) (According to load ratio100%-80%/80%-70%/70%-60%/60%-0) |
|||||
| Maximumconesion votage | 300 VAC±5% | |||||
| Maximum recovery votage | 290 VAC±5% | |||||
| Frequency range | 40Hz~70Hz | |||||
| Phase | Single phase grounded type | |||||
| Power specifications | ≥0.99@220-230 VAC(input voltage) | |||||
| Output voltage | 200/208/220/230/240 VAC | |||||
| Range of mains voltage | ±1%(Battery mode) | |||||
| Frequency range (synchronous range) |
47~53 Hz or57~63 Hz | |||||
| Frequency range (battery mode) |
50Hz±0.25Hz or 60Hz±0.3Hz | |||||
Overload |
The ambient temperature is less than 35 degrees Celsius: 105%~110%:UPS will automatically shut down after 10 minutes in battery mode,or switch to bypass mode when input is normal; 110%~130%:UPS will automatically shut down after1minute in battery mode,or switch to bypass mode when input is normal; >130%:UPS automatically shuts down after 3 seconds in battery mode,or switches to bypass mode when input is normal 3:1 |
|||||
| Current to peak ratio | ≤3%THD(linear load);≤5%THD(non-linear load) | |||||
| Harmonic distortion | zero | |||||
| From mains mode to battery mode | 4ms(Under standard conditions) | |||||
| Variable frequencyt bypass | Pure sine wave | |||||
| Waveform(battery mode) | ||||||
| Mains mode | 89% | 90% | ||||
| Battery mode | 87% | 88% | ||||
| Battery | Battery capacity | Depending on the external battery | ||||
| Number of batteries | 4 | 6 | 6 | 8 | ||
| Charging current | 1A/2A/4A/6A | |||||
| Charging voltage | 54.7 VDC±1% | 82.0 VDC±1% | 82.0 VDC±1% | 109.4 VDC±1% | ||
| lemmitonti | Size depth,width and height(mm) | 430×190X340 | ||||
| Net weight(kg) | 17.58 | 9.48 | 22.12 | 10.03 | ||
| m dpearance | Operating humidity | 20-90%RH@0-40ºC(No condensation) | ||||
| Noise | Less than 50dBA@1 rice | |||||
| stration | Intelligent RS-232 or USB(Apolegamy) | support Windows@2000/2003/XP/Vista/2008/7,Linux,Unix or MAC | ||||
| ApolegamySNMP | Supports power management by SNMP administrators and web browsers | |||||
| C6K(S) | ||||||||||||
| Capacity* | 6KVA/4800W | 10KVA/8000W | 10KVA/8000W | 15KVA/12000W | 20KVA/16000w | |||||||
| output input | Voltage range | M | inimum conesionvotg | el At 50%load,110VAC±3%;176VAC±3%at 100%load | ||||||||
| Minimum recovery votag | e Minimum conversion voltage+10V | |||||||||||
| Maimumcnversio votg | e 300VAC±3% | |||||||||||
| Maximum recovery votag | e Maximum conversion voltage-10V | |||||||||||
| frequency range | 46Hz-54Hz@50Hz OS;56Hz-64Hz@60Hz System | |||||||||||
| phase | Single phase grounded type | Three phase with neutral grounding | ||||||||||
| Power factor | 100%Under load≥0.99 | |||||||||||
| Output voltage | 208/220/230/240VAC | |||||||||||
| AC Voltage range | ±1% | |||||||||||
| Frequency range (synchronous range) |
46Hz-54Hz@50Hz OS;56Hz-64Hz@60Hz System | |||||||||||
| Frequency range (battery mode) |
50Hz±0.1Hz or 60Hz±0.1Hz | |||||||||||
| Overload | AC pattern |
100%-110%:10minute; 110%-130%:1minute; >130%:1 second |
100%-110%:30minute; 110%-130%:5minute; >130%:1second |
100%-110%:15minute; 110%-130%:30second; >130%:1second |
||||||||
Battery mode |
100%-110%:30second; 110%-130%:10second; >130%;1second |
100%-110%:3minute; 110%-130%:30second; >130%:1second |
100%-110%:5minute; 110%-130%:1second; >130%:Immediate action |
|||||||||
| Current to peak ratio | 3:1(Maximum value) | |||||||||||
| Harmonic distortion | ≤3%THD linear load;≤6%THD nonlinear load | |||||||||||
| nsformation time |
Municipal electricity →Battery | 0ms | ||||||||||
| Inversion→Bypass | 4ms(Under standard conditions) | |||||||||||
| Battery fficiency | AC Pattern | >90% | 91% | |||||||||
| Battery mode | 88% | 91% | ||||||||||
| ion machine Standard | Model and quantity | 12V/7 Ah Or12V/9Ahx16 | ||||||||||
| Charging time | Achieve 90%capacity in 9 hours | |||||||||||
| Charging current | Preset:1A±10%;Maximum value:2A | |||||||||||
| Charging voltage | 218.4VDC±1% | |||||||||||
| machine | Model | Varies according to purpose | ||||||||||
| Quantity | 16-20(Adjustable,subject to physical condition) | |||||||||||
| Charging current | Preset:4A±10%:Maximum value:6A±10% | |||||||||||
| Charging voltage | Nx13.65VDC±1%(N is the number of batteries) | |||||||||||
| n Environment condition Appearance | luegtnmitne san | Size: deep×widexhigh |
500*240*616(mm) |
|||||||||
| Net weight(KG) | 57 | 63 | 64 | 66 | 66 | |||||||
| did nathne | Size: deep×widexhigh |
500*240*616(mm) |
||||||||||
| Net weight(KG | ) 19 | 22 | 31 | 33 | 33 | |||||||
| Operating temperat | ure | 0-40°ºC(The battery life will be shortened in environments above 25ºC) | ||||||||||
| Operating humidity | <95%RH without condensation | |||||||||||
| Operating altitude** | <1000m | |||||||||||
| Noise | less than 55dB@1 Meter | less than 58dB@1 Meter | ||||||||||
| IntelligentRS-232 or USB(Optional configuration) | Support Windows2000/2003/XP/Vista/2008,Windows7/8,Linux.UnixMAC |
|||||||||||
| Optional configuration SNMP | Supports power management by SNMP administrators and web browsers | |||||||||||
| Capacity* | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | |||||
| output input | M M |
Minimum conversion otag | 160 VAC/140 VAC/120 VAC/110 VAC±5%(The ambient temperature is less than 35 degrees Celsius) e (According to load ratio 100%-80%/80%-70%/70%-60%/60%-0) | |||||
Minimum recoveryvoltage |
175 VAC/155 VAC/135 VAC/125 VAC±5%(The ambient temperature is less than 35 degrees Celsius) (According to load ratio100%-80%/80%-70%/70%-60%/60%-0) |
|||||||
| aximumcnesonvotage | g 300 VAC±5% | |||||||
| aximum recoveryvoltag | e 290 VAC±5% | |||||||
| Frequency range | 40Hz~70Hz | |||||||
| Phase | Single phase grounded type | |||||||
| Power specifications | ≥0.99@220-230 VAC(input voltage) | |||||||
| Output voltage | 200/208/220/230/240 VAC | |||||||
| Range of mains voltage | ±1%(Battery mode) | |||||||
| Frequency range (synchronous range) |
47~53 Hz or57~63Hz | |||||||
| Frequency range (Battery mode) |
50Hz±0.25Hz or 60Hz±0.3Hz | |||||||
Overload |
The ambient temperature is less than 35 degrees Celsius: 105%~110%:UPS will automatically shut down after 10 minutes in battery mode,or switch to bypass mode when input is normal; 110%~130%:UPS will automatically shut down after 1minute in battery mode,or switch to bypass mode when input is normal; >130%:UPS automatically shuts down after 3 seconds in battery mode,or switches to bypass mode when input is normal |
|||||||
| Current to peak ratio | 3:1 | |||||||
| Harmonic distortion | ≤3%THD(Linear load);≤5%THD(Nonlinear load) | |||||||
| From mains mode to battery mode | zero | |||||||
| Variable frequency to bypass | 4ms(Under standard conditions) | |||||||
| Waveform (battery mode) | Pure sine wave | |||||||
| Efcency | Mains mode | 88% | 89% | 90% | ||||
| Battery mode | 83% | 87% | 88% | |||||
| Battery | Battery capacity | Depending on the external battery | ||||||
| Number of batteries | 2 | 3 | 4 | 6 | 6 | 8 | ||
| Charging current | 1A/2A/4A/6A | |||||||
| Charging voltage | 27.3 VDC±1% | 41.0VDC±1% | 54.7 VDC±1% | 82.0 VDC±1% | 82.0 VDC±1% | 109.4 VDC±1% | ||
| tion Envromen | Size depth,width and height(mm) | 355X145X225 | 430×190X340 | |||||
| Net weight(kg) | 8.65 | 6.0 | 17.58 | 9.48 | 22.12 | 10.03 | ||
| t cond ion Appeara | Operating humidity | 20-90%RH@0-40°ºC(No condensation) | ||||||
| Noise | Less than 50dBA@1 rice | |||||||
| nce | Intelligent RS-232 or USB(apolegamy) | Support Windows@2000/2003/XP/Vista/2008/7,Linux,Unix or MAC | ||||||

Q1. How long is your lead time?